Sign In | Join Free | My entremaqueros.com
China Shenzhen XUWEN Technology Co.,Ltd logo
Shenzhen XUWEN Technology Co.,Ltd
Factory of lithium-ion battery packs, lithium battery protection management systems, lithium battery testing equipment.
Active Member

4 Years

Home > LiFePO4 BMS Battery Management System >

4S 12.8V 8A LiFePO4 BMS Battery Management System With 20A Current Limit

Shenzhen XUWEN Technology Co.,Ltd
Contact Now

4S 12.8V 8A LiFePO4 BMS Battery Management System With 20A Current Limit

  • 1
  • 2

Brand Name : XUWEN

Model Number : 4s 8a lifepo4 bms

Certification : ISO9001/Iso14001/CE/ROHS

Place of Origin : China

MOQ : 5PCS

Price : To be negotiated

Payment Terms : T/T, Western Union, MoneyGram

Supply Ability : 100000pcs/month

Delivery Time : To be negotiated

Packaging Details : Packed in export carton Box

Upper limit operating current : 8A

Upper limit instantaneous current : 20A

Overcharge voltage range : 3. 65V±0. 05v

Quiescent Current : <30u

Charging voltage : 14. 4V-15V

Contact Now

4S 12.8V 8A LiFePO4 BMS Battery Management System Lithium Iron Phosphate Battery Protection Board 20A Current Limit

Feature:
Upper limit operating current: 8A
Upper limit instantaneous current: 20A
Overcharge voltage range: 3. 65V±0. 05v
Quiescent Current: <30u
Charging voltage: 14. 4V-15V


Note:
Lithium iron phosphate protection plate cannot be used for xenon lamps,
Hand drill battery pack, power tool battery pack, electric fish
Machine battery pack, vacuum cleaner, sweeper battery pack,
Electric bicycle battery pack, baby car battery, 550 or more
Power motor, IW fisheye LED light
For discharge products above 3A, the battery discharge rate should be 3C or more.
Magnification formula: IC rate battery, 2000 capacity equals 2AH*1=2A working current 3C rate battery,2000 capacity is equal to 2AH*3=6A working current.
In the use of the battery will be hot, the battery rate is not applicable, this situation can not be used for a long time, the battery will be damaged quickly.


Package Included:
1 * Battery Protection Board

4S 12.8V 8A LiFePO4 BMS Battery Management System With 20A Current Limit4S 12.8V 8A LiFePO4 BMS Battery Management System With 20A Current Limit

RFQ

1.What is the common port and separate port? what is the difference?
We take 13S 48V 15A BMS as an example, common port 15A means your charge cathode and discharge cathode are connected in the same point end(our P-), charge cathode and discharge cathode are used in the common connection
port, so the charge current and discharge current are the same 15A. while the separate port is separately connected by charge cathode (C-) and discharge cathode (P-), so the charge current and discharge current are different, discharge current 15A, charge current 8A.

2.What is the balance function?
The working principle and function are as followings, when your one cell voltage is upto alarm voltage(Li-ion upto 4.18V, LifePo4 upto (3.6V), then the cell Balance starts to work, balance resistance starts discharge with 35ma(when balance discharge starts to work, BMS will starts a little heat up, which is the normal reflection), the cell is in both charging and discharging status, and others which are not reached to alarm voltage(Li-ion 4.18V, LifePo4 3.6V)are only in charging status, no discharging, when the fast cell voltage is reached to alarm voltage (Li-ion 4.25V, LifePo4 3.75V) BMS starts off power protection, all the other cells are all in stop of charging, this process will enable your battery charging in balance current, and your battery voltage are in balance status, but when your cell voltage difference are in a big range, then balance can not be functionning well

3.The relationship between Battery capacity and BMS current?
There is no direct relationship between Battery capacity and BMS current, big capacity doesn`t mean a big battery, but rely on continue current, that is to say if your engine is powerful, your should choose high current of BMS, it is not relied on battery capacity.

4. What type of charger should I choose?
Lithium battery must choose specific charger, do not use Charger for Leadacid battery, for leadacid charger may have MOS with high pressure breakdown protection, which will not protect of BMS over charge. Life Po4 battery charger voltage=battery string No.X3.6V, while Li-ion battery charger voltage=Battery string No.X4.2V.

5. What current BMS should I choose ?
Take 10S 36V as an example: what current BMS you choose is relied on your E-bicycle Motor power and current limitation of controller. eg., choose 15A for below 350W, 20A for below 500W, 30A for below 800W, 60A for Below 1000W, higher than 1200W are contact with our service specialist for suggestions, one inall, continue current shall be higher than current limitation in Controller.

6. Whether my BMS damaged?
if you want to judge if the BMS is damaged, please take the folowing steps, to test if each cell voltage is the same with
voltmeter? if the cell voltage difference is over 1.0V, the fault is displayed that it cannot run far, no power supply at the
start range, short charge time, all these issues are almost caused by battery cells, if BMS damaged is displyed as no charge, no discharge, no discharge while the battery has voltage.


Product Tags:

12.8V LiFePO4 BMS Battery Management System

      

8A LiFePO4 BMS Battery Management System

      

20A Current Limit 4S LIFEPO4 BMS

      
 4S 12.8V 8A LiFePO4 BMS Battery Management System With 20A Current Limit Manufactures

4S 12.8V 8A LiFePO4 BMS Battery Management System With 20A Current Limit Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Shenzhen XUWEN Technology Co.,Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)